例題
設(shè)計條件:Td=425℃,Pd=0.6MPaG,[Nc]=1000Cy,304鋼
波紋管尺寸數(shù)據(jù):Db=1100mm,w=65mm,q=60mm,t=1.2mm,n=3,Lt=40mm
設(shè)計計算結(jié)果:基于柱失穩(wěn)的多容許波數(shù)Nmax=11,[e]=20mm,[ee]=10mm,[ec]=20mm
(1)軸向膨脹節(jié)
N=2:[x]=40mm,[xe]=20mm,[xc]=40mm
N=4:[x]=80mm,[xe]=40mm,[xc]=80mm
N=6:[x]=120mm,[xe]=60mm,[xc]=120mm
N=8:[x]=160mm,[xe]=80mm,[xc]=160mm
N=10:[x]=200mm,[xe]=100mm,[xc]=200mm
(2)角向膨脹節(jié)
N=2:[Θ]=2.0°
N=4:[Θ]=4.0°
N=6:[Θ]=6.0°
(3)橫向膨脹節(jié)
N=3+3,Lc=500mm,[y]=29mm
N=3+3,Lc=1000mm,[y]=53mm
N=3+3,Lc=1500mm,[y]=78mm
N=3+3,Lc=2000mm,[y]=103mm
注:Lc為中接管長度。
(4)膨脹節(jié)
N=3+3,Lc=500mm,[x]=120mm,[xe]=60mm,[xc]=120mm,[y]=29mm
N=3+3,Lc=1000mm,[x]=120mm,[xe]=60mm,[xc]=120mm,[y]=53mm
N=3+3,Lc=1500mm,[x]=120mm,[xe]=60mm,[xc]=120mm,[y]=78mm
N=3+3,Lc=2000mm,[x]=120mm,[xe]=60mm,[xc]=120mm,[y]=103mm